Draft measurement system
• Accuracy : ± 2,5 mm.
• Principle of measurement : Controled bubbler.
• Measurement compensation : sensorcharacteristic, temperature offset&span and automatic zerocorrection.
• Supply pressure : 3..10 bar
• Maximum airflow per measurepoint : 10 liter per hour
• Measure range : 0..10 meter watercolumn.
• Temperature range measure unit : 0..+60ºC
• Supply voltage : 22..30VDC of 220VAC
• Clinometerlamp output : 1 A / 30V
• Maximum distance to measurepoint : 300 meter
• Control : RS232
Height measurement system
• Accuracy : ± 0,5 mm.
• Principle of measurment : liquid weighing.
• Temperature range measure unit : 0..+60ºC
• Supply voltage : 22..30VDC of 220VAC
• Maximum distance to measurepoint : 30 meter
• Control : RS232
DeckTV
• Range : 150 meter (sender in sight)
• Weight : 600 gram
• Dimensions : 200x110x30mm
• 100% waterproof (it’s floats)
• Supplied with neckcord.
• Accu : 14,4 V
• Charging voltage : 24 V
• Charging time : 12 uur
• Time of use : 24 uur (normal), 1uur15min (continuous).
• Temperature range measure unit : -10..+50ºC.
• Receiver frequency : 2,4 Ghz
Tank measurement system
• Accuracy : ± 2,5 mm.
• Principle of measurement : Controled bubbler.
• Measurement compensation : sensorcharacteristic, temperature offset&span and automatic zerocorrection.
• Supply gas : compressed air or nitrogen.
• Supply pressure : 3..10 bar
• Maximum airflow per measurepoint : 0,1 liter per hour
• Measure range : 0..10 meter watercolumn.
• Temperature range measure unit : 0..+60ºC
• Supply voltage : 22..30VDC of 220VAC
• Clinometerlamp output : 1 A / 30V
• Maximum distance to measurepoint : 300 meter
• Control : RS232